MENU
Toggle navigation
Products
Pump & Bottle Sets
Cone Top Bottles
Wash Bottles
Trigger Sprayer Bottles
Flux Dispensers
One-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Tin-Plate Bottle
Lasting-Touch Dispensers
HDPE (High Density Plastic) Bottles
Glass Bottles
Pure-Take Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Tin-Plate Bottle
Pure-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Take-Along Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Twist-Lock Locking Dispensers
Black Pump
Purple Pump
White Pump
Pump & Bottle Accessories
Replacement Stems
Bottle Closures
Replacement Needles
Pumps Only
Lasting-Touch Pump
One-Touch Pump
Pure-Touch Pump
Pure-Take Locking Pump
Take-Along Locking Pump
Twist-Lock Locking Pump
Bottles Only
HDPE (High Density Plastic)
Blue durAstatic®
Green durAstatic®
Orange durAstatic®
Pink
Purple
White (No Colors Added)
Yellow durAstatic®
Badge & ID Holders
Color Badge Holders
Clear Vinyl Badge Holders
Shielded Badge Holders
Arm Badge
Badge Reels, Lanyards, & Strap Clips
Cable Management
Cable Control
Connector Covers & Dust Caps
Circular Connectors
D-Sub Connectors
Document Holders
With Zipper
No-Zipper
Drinking Cup
Fume Extractors
Series II System (1-2 Operators)
Complete System
Accessories
Replacement Filters
Hand & Power Tools
Cleaning Brushes
Conductive (Black Bristles)
Dissipative (Yellow Nylon Bristles)
Circuitracer™ Continuity Tester
IC Tube End Plug Extractor
Probes & Spudgers
Nylon
Steel
Wood
Screw Removal Pliers
Sleeve & Tubing Cutter
Small Nut Starter
Tool Storage
Wire & Harness Threader
Lotion
Probes, Spudgers, Soldering Aids
Double Ended Soldering Aids
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
Soldering & Rework
Desoldering Braid
Lead-Free
One-Step
Quick Braid
Sea Braid
Solder Tip Cleaners
Stencil Rolls & Wipes
DEK
EKRA
MPM
YAMAHA
Vacuums
Blow Vac
ESD Service Vacuum
HEPA Vac
Workstation Organizers
Overstock & Clearance Deals
EasyBraid Products
ID & Vinyl Products
MENDA Pump Dispensers
Specialty Tools & Accessories
Workstation Organizers
Vacuums
ESD Products
ESD Liquid Dispenser
ESD durAstatic® Bottles Only
ESD Badge Holders
ESD Brushes
ESD Cable Control
ESD Conductive Connector Covers
ESD Drinking Cup
ESD Flux Bottles
ESD Fume Extractor & Accessories
ESD Lotion
ESD Workstation Organizers
ESD Document Holders
ESD Testers, Probes & Tools
ESD Vacuums & Accessories
ESD Clearance & Overstock
Beau Tech Products
Cleaning Brushes
Double Ended Soldering Aids
Hand Tools
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
EasyBraid Products
Desoldering Braid
Stencil Rolls
Solder Tip Cleaners
WickGun Desoldering Braid Dispenser
Badge & ID Holders
Clear Vinyl Badge Holders
Color Badge Holders
Document Holders
Horizontal Badges
Vertical Badges
Proximity Card Badge Holders
Multi-Card Badge Holders
Shielded Badge Holders
Event Badge Holders
Flap Closure Badge Holders
Zipper Closure Badge Holders
Arm Badges
Badge Reels
Strap Clips
Lanyards
Resources
Videos
REGISTER / LOGIN
SHOP
RPL
CART (
0
)
Questions And Answers
#
1180
List All Questions
Search
List by Category
Question
Dear Sir / Madam
I have a question regarding ESD safety when working with AC voltages (240V AC).
We are an electronics company and obviously we have all ESD pre-cautions to safe guard our products. We started buying such products directly from you and I require your help on the following issue. Apart from the standard products that we produce using 5V DC, 9V DC and 12V DC, we have a specified model that works with 240V AC and therefor needs to be tested with such supply input.
Our operators all wear a heel strap / wrist strap with a 1 MOhm resistance. My questions are:
1. Is it safe for the operator to wear such heel strap when working on 240V AC?
2. Is the operator safe if he is wear such heel strap and accidentally touches the AC connection and takes an electric shock?
3. Would such heel strap effects positively or negatively when taking the shock?
Kindly send me the required information, preferably with some technical info as soon as possible.
Best Regards & Thanks for your support.
Answer
When working with voltages over 250 VAC, ESD personnel grounding should not be used, rather ionization may be required to neutralize electrostatic charges. As important as ESD control is, it is of secondary importance compared to employee safety. Questions regarding safety should be answered by the facility’s safety officer. The Safety Officer has to make the determination if the worker has any risk of being exposed to the high voltage. If the Safety Officer determines that the high voltage is adequately insulated and isolated, then personnel grounding, which is more effective and less expensive, can be used. If operators are being shocked the source should be identified and eliminated. If exposure is to elect rical line voltage, a licensed electrician should perform this work.
Per ESD-S1.1 Current-Limiting Resistance “A resistance value incorporated in series with the wrist strap’s electrical path to ground. This resistance limits electrical current that could pass through the ground cord in the event of inadvertent user contact with electrical potential.” This should cover your 240 volt application.
However, when working with voltages over 250 VAC, ESD personnel grounding should not be used, rather ionization may be required to neutralize electrostatic charges. Per ESD Handbook TR 20.20 paragraph 5.3.6.1 Introduction and Purpose / General Information “The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g., most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring and footwear. Air ionization can neutralize the static charge on insulated and isolated objects by charging the molecules of the gases of the surrounding air.”
ESD Systems.com Wrist Straps [and many Foot Grounders] are Underwriter Laboratories listed. UL cautions that these products are not recommended for use on equipment with operating voltage exceeding 250 volts recommending that the electrical current that the operator be exposed to be limited to 0.70 milliamp. At 250 volts, a 1 megohm [1,000,000 ohms] resistor limits current to 0.25 milliamp.
UL Marking for Wrist Straps and Foot Grounders:
CAUTIONARY MARKING
This product is not recommended for use on equipment with operating voltage exceeding 250 volts.A one megohm resistor is molded into Wrist Strap Coil Cords. DO NOT REMOVE. If it becomes damaged, replace Coil Cord immediately. These products are not to be used in areas where the individual may come in contact with exposed electrical circuitry exceeding 250 volts. These products are for ElectroStatic control. They will not reduce or increase your risk of receiving electrical shock when using or working on electrical equipment. Follow the same precautions you would use without wrist straps, including:. Make certain that equipment having a grounding type plug is properly grounded.
Make certain that you are not in contact with grounded objects other than through the Wrist Strap.
Per ESD Handbook TR20.20 section 5.3.2.6 Current Limiting “Most wrist straps have a current limiting resistor molded into the ground cord head on the end that connects to the cuff. The resistor most commonly used is a one megohm, ¼ watt with a working voltage rating of 250 volts. Resistors limit current as defined by Ohm’s Law, which states the current is equal to the voltage divided by the resistance.
In a practical application, the maximum amount of current through a wrist strap ground cord if it was placed across a 250 Volt source is 250 microamps or 0.25 milliamps. This amount of current is well below the 0.7 milliamps that Underwriters Laboratories uses as the peak current in a LIMITED CURRENT CIRCUIT. See document UL 1950.
Per ESD Handbook TR 20.20 section 5.3.13.6 Other Considerations “For personnel safety, static control garments should not be worn in situations where there is exposure to high voltage.”When both Foot Grounders are in contact with the ESD Floor, the resistance is in parallel or halved; you should consider using Foot Grounders that have 2 Megohm resistor.