!
MENU
Toggle navigation
Products
Pump & Bottle Sets
Cone Top Bottles
Wash Bottles
Trigger Sprayer Bottles
Flux Dispensers
One-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Tin-Plate Bottle
Lasting-Touch Dispensers
HDPE (High Density Plastic) Bottles
Glass Bottles
Pure-Take Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Tin-Plate Bottle
Pure-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Take-Along Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Twist-Lock Locking Dispensers
Black Pump
Purple Pump
White Pump
Pump & Bottle Accessories
Replacement Stems
Bottle Closures
Replacement Needles
Pumps Only
Lasting-Touch Pump
One-Touch Pump
Pure-Touch Pump
Pure-Take Locking Pump
Take-Along Locking Pump
Twist-Lock Locking Pump
Bottles Only
HDPE (High Density Plastic)
Blue durAstatic®
Green durAstatic®
Orange durAstatic®
Pink
Purple
White (No Colors Added)
Yellow durAstatic®
Badge & ID Holders
Color Badge Holders
Clear Vinyl Badge Holders
Shielded Badge Holders
Arm Badge
Badge Reels, Lanyards, & Strap Clips
Cable Management
Cable Control
Connector Covers & Dust Caps
Circular Connectors
D-Sub Connectors
Document Holders
With Zipper
No-Zipper
Drinking Cup
Fume Extractors
Series II System (1-2 Operators)
Complete System
Accessories
Replacement Filters
Hand & Power Tools
Cleaning Brushes
Conductive (Black Bristles)
Dissipative (Yellow Nylon Bristles)
Circuitracer™ Continuity Tester
IC Tube End Plug Extractor
Probes & Spudgers
Nylon
Steel
Wood
Screw Removal Pliers
Sleeve & Tubing Cutter
Small Nut Starter
Tool Storage
Wire & Harness Threader
Lotion
Probes, Spudgers, Soldering Aids
Double Ended Soldering Aids
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
Soldering & Rework
Desoldering Braid
Lead-Free
One-Step
Quick Braid
Sea Braid
Solder Tip Cleaners
Stencil Rolls & Wipes
DEK
EKRA
MPM
YAMAHA
Vacuums
Blow Vac
ESD Service Vacuum
HEPA Vac
Workstation Organizers
Overstock & Clearance Deals
EasyBraid Products
ID & Vinyl Products
MENDA Pump Dispensers
Specialty Tools & Accessories
Workstation Organizers
Vacuums
ESD Products
ESD Liquid Dispenser
ESD durAstatic® Bottles Only
ESD Badge Holders
ESD Brushes
ESD Cable Control
ESD Conductive Connector Covers
ESD Drinking Cup
ESD Flux Bottles
ESD Fume Extractor & Accessories
ESD Lotion
ESD Workstation Organizers
ESD Document Holders
ESD Testers, Probes & Tools
ESD Vacuums & Accessories
ESD Clearance & Overstock
Beau Tech Products
Cleaning Brushes
Double Ended Soldering Aids
Hand Tools
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
EasyBraid Products
Desoldering Braid
Stencil Rolls
Solder Tip Cleaners
WickGun Desoldering Braid Dispenser
Badge & ID Holders
Clear Vinyl Badge Holders
Color Badge Holders
Document Holders
Horizontal Badges
Vertical Badges
Proximity Card Badge Holders
Multi-Card Badge Holders
Shielded Badge Holders
Event Badge Holders
Flap Closure Badge Holders
Zipper Closure Badge Holders
Arm Badges
Badge Reels
Strap Clips
Lanyards
Resources
Videos
REGISTER / LOGIN
SHOP
RPL
CART (
0
)
Questions And Answers
#
1500
List All Questions
Search
List by Category
Question
What should be done with insulators for ESD control?
Answer
Insulators, by definition, are non-conductors and therefore cannot be grounded. Besides neutralization using ionizers, insulators can be controlled by doing one of the following: Remove insulator from the ESD protected area (EPA); Keep insulators a minimum of 12" from ESDS items at all times; Replace regular insulative items with an ESD protective version; Periodically apply a coat of topical antistat. When none of the above is possible, the insulator is termed process essential and therefore neutralization using an ionizer should become a necessary part of the ESD control program.Per ANSI/ESD S20.20-2007 section 8.3 "All nonessential insulators such as coffee cups, food wrappers and personal items shall be removed from the workstation or any operation where unprotected ESDS items are handled." Per ESD Handbook ESD TR20.20-2008 Ionization, section 5.3.6.1 Introduction and Purpose / General Information "The primary method of static charge control is direct connection to ground for conductors, static dissipative materials, and personnel. A complete static control program must also deal with isolated conductors that cannot be grounded, insulating materials (e.g. most common plastics), and moving personnel who cannot use wrist or heel straps or ESD control flooring or footwear. Air ionization is not a replacement for grounding methods. It is one component of a complete static control program. Ionizers are used when it is not possible to properly ground everything and as backup to other static control methods."
Related Categories:
Grounding
Ionization
Tape
Materials
If you have found this Q/A useful, please rate it based on its helpfulness.
This question has been rated:
(
0
% at
0
Ratings)
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Review our
Cookies Policy
for more information.
Accept