MENU
Toggle navigation
Products
Pump & Bottle Sets
Cone Top Bottles
Wash Bottles
Trigger Sprayer Bottles
Flux Dispensers
One-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Tin-Plate Bottle
Lasting-Touch Dispensers
HDPE (High Density Plastic) Bottles
Glass Bottles
Pure-Take Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Tin-Plate Bottle
Pure-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Take-Along Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Twist-Lock Locking Dispensers
Black Pump
Purple Pump
White Pump
Pump & Bottle Accessories
Replacement Stems
Bottle Closures
Replacement Needles
Pumps Only
Lasting-Touch Pump
One-Touch Pump
Pure-Touch Pump
Pure-Take Locking Pump
Take-Along Locking Pump
Twist-Lock Locking Pump
Bottles Only
HDPE (High Density Plastic)
Blue durAstatic®
Green durAstatic®
Orange durAstatic®
Pink
Purple
White (No Colors Added)
Yellow durAstatic®
Badge & ID Holders
Color Badge Holders
Clear Vinyl Badge Holders
Shielded Badge Holders
Arm Badge
Badge Reels, Lanyards, & Strap Clips
Cable Management
Cable Control
Connector Covers & Dust Caps
Circular Connectors
D-Sub Connectors
Document Holders
With Zipper
No-Zipper
Drinking Cup
Fume Extractors
Series II System (1-2 Operators)
Complete System
Accessories
Replacement Filters
Hand & Power Tools
Cleaning Brushes
Conductive (Black Bristles)
Dissipative (Yellow Nylon Bristles)
Circuitracer™ Continuity Tester
IC Tube End Plug Extractor
Probes & Spudgers
Nylon
Steel
Wood
Screw Removal Pliers
Sleeve & Tubing Cutter
Small Nut Starter
Tool Storage
Wire & Harness Threader
Lotion
Probes, Spudgers, Soldering Aids
Double Ended Soldering Aids
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
Soldering & Rework
Desoldering Braid
Lead-Free
One-Step
Quick Braid
Sea Braid
Solder Tip Cleaners
Stencil Rolls & Wipes
DEK
EKRA
MPM
YAMAHA
Vacuums
Blow Vac
ESD Service Vacuum
HEPA Vac
Workstation Organizers
Overstock & Clearance Deals
EasyBraid Products
ID & Vinyl Products
MENDA Pump Dispensers
Specialty Tools & Accessories
Workstation Organizers
Vacuums
ESD Products
ESD Liquid Dispenser
ESD durAstatic® Bottles Only
ESD Badge Holders
ESD Brushes
ESD Cable Control
ESD Conductive Connector Covers
ESD Drinking Cup
ESD Flux Bottles
ESD Fume Extractor & Accessories
ESD Lotion
ESD Workstation Organizers
ESD Document Holders
ESD Testers, Probes & Tools
ESD Vacuums & Accessories
ESD Clearance & Overstock
Beau Tech Products
Cleaning Brushes
Double Ended Soldering Aids
Hand Tools
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
EasyBraid Products
Desoldering Braid
Stencil Rolls
Solder Tip Cleaners
WickGun Desoldering Braid Dispenser
Badge & ID Holders
Clear Vinyl Badge Holders
Color Badge Holders
Document Holders
Horizontal Badges
Vertical Badges
Proximity Card Badge Holders
Multi-Card Badge Holders
Shielded Badge Holders
Event Badge Holders
Flap Closure Badge Holders
Zipper Closure Badge Holders
Arm Badges
Badge Reels
Strap Clips
Lanyards
Resources
Videos
REGISTER / LOGIN
SHOP
RPL
CART (
0
)
Questions And Answers
#
219
List All Questions
Search
List by Category
Question
Are there any hard and fast requirements for control of relative humidity in ESD Protected Areas now that MIL-STD-1695 has been cancelled without replacement. If not, where can I find what specific additional ESD controls should be placed in effect when RH drops below 20%? Thank you for any guidance you can provide. - Anonymous, Austin, TX
Answer
The standard, ANSI/EIA-625-1994, section 11.2 recommends a minimum humidity of 40% R.H. Since tribocharging will be producing higher voltages it’s critical for the user to obtain high compliance to a rigid ESD control program. Items that might be employed in any environment would be essential in an environment below 20% RH, such as: Use of static shielding bags which create a Faraday cage to protect ESD sensitive components at all times when they are stored or being transported; Overhead and Bench Ionizers to neutralize static charges from insulators; Use of Continuous Monitors to ensure that workstations, both ESD mat and wrist strap, are properly grounded. Note: continuous monitors require utilizing worksurface resistance to ground (RTG) of 5 x 10^8 ohms or below. If periodic testing is utilized, workers should check their wrist straps and foot grounders at least twice a day. Mat and surfaces must be cleaned with a silicone-free ESD Cleaner. Silicone is an insulator and will prevent mats from properly draining away static charges. Coil cords should be of durable single-wire designed utilizing contoured supported banana plugs to improve reliability preventing breaks in grounding circuit. Use of dissipative smocks or lab coats to provide a Faraday Cage around static charges generated by movement of worker’s clothing. Use of dissipative floor finish and two foot grounders per person to reduce tribocharging from movement across the floor, and ensure the proper draining of static charges from personnel, carts, etc. An alternative is the use of dissipative or conductive floor mats that are permanently attached to a proper ground. Removal of all non-essential items from the ESD work area. Any tapes, clip boards, binders, document carriers, waste can liners used should be anti-static versions. Topical antistat treatment should be sprayed on all non-static surfaces. Use of CD ROM and other training tools to ensure worker understanding of Compliance efforts should be increased using Test Equipment to ensure that flooring and mats have proper electrical properties.