!
MENU
Toggle navigation
Products
Pump & Bottle Sets
Cone Top Bottles
Wash Bottles
Trigger Sprayer Bottles
Flux Dispensers
One-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Tin-Plate Bottle
Lasting-Touch Dispensers
HDPE (High Density Plastic) Bottles
Glass Bottles
Pure-Take Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Tin-Plate Bottle
Pure-Touch Dispensers
Glass Bottle
HDPE (High Density Plastic) Bottle
Take-Along Locking Dispensers
HDPE (High Density Plastic) Bottle
Glass Bottle
Twist-Lock Locking Dispensers
Black Pump
Purple Pump
White Pump
Pump & Bottle Accessories
Replacement Stems
Bottle Closures
Replacement Needles
Pumps Only
Lasting-Touch Pump
One-Touch Pump
Pure-Touch Pump
Pure-Take Locking Pump
Take-Along Locking Pump
Twist-Lock Locking Pump
Bottles Only
HDPE (High Density Plastic)
Blue durAstatic®
Green durAstatic®
Orange durAstatic®
Pink
Purple
White (No Colors Added)
Yellow durAstatic®
Badge & ID Holders
Color Badge Holders
Clear Vinyl Badge Holders
Shielded Badge Holders
Arm Badge
Badge Reels, Lanyards, & Strap Clips
Cable Management
Cable Control
Connector Covers & Dust Caps
Circular Connectors
D-Sub Connectors
Document Holders
With Zipper
No-Zipper
Drinking Cup
Fume Extractors
Series II System (1-2 Operators)
Complete System
Accessories
Replacement Filters
Hand & Power Tools
Cleaning Brushes
Conductive (Black Bristles)
Dissipative (Yellow Nylon Bristles)
Circuitracer™ Continuity Tester
IC Tube End Plug Extractor
Probes & Spudgers
Nylon
Steel
Wood
Screw Removal Pliers
Sleeve & Tubing Cutter
Small Nut Starter
Tool Storage
Wire & Harness Threader
Lotion
Probes, Spudgers, Soldering Aids
Double Ended Soldering Aids
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
Soldering & Rework
Desoldering Braid
Lead-Free
One-Step
Quick Braid
Sea Braid
Solder Tip Cleaners
Stencil Rolls & Wipes
DEK
EKRA
MPM
YAMAHA
Vacuums
Blow Vac
ESD Service Vacuum
HEPA Vac
Workstation Organizers
Overstock & Clearance Deals
EasyBraid Products
ID & Vinyl Products
MENDA Pump Dispensers
Specialty Tools & Accessories
Workstation Organizers
Vacuums
ESD Products
ESD Liquid Dispenser
ESD durAstatic® Bottles Only
ESD Badge Holders
ESD Brushes
ESD Cable Control
ESD Conductive Connector Covers
ESD Drinking Cup
ESD Flux Bottles
ESD Fume Extractor & Accessories
ESD Lotion
ESD Workstation Organizers
ESD Document Holders
ESD Testers, Probes & Tools
ESD Vacuums & Accessories
ESD Clearance & Overstock
Beau Tech Products
Cleaning Brushes
Double Ended Soldering Aids
Hand Tools
Orange Sticks
Probes and Spudgers
Soldering Aid Kits
EasyBraid Products
Desoldering Braid
Stencil Rolls
Solder Tip Cleaners
WickGun Desoldering Braid Dispenser
Badge & ID Holders
Clear Vinyl Badge Holders
Color Badge Holders
Document Holders
Horizontal Badges
Vertical Badges
Proximity Card Badge Holders
Multi-Card Badge Holders
Shielded Badge Holders
Event Badge Holders
Flap Closure Badge Holders
Zipper Closure Badge Holders
Arm Badges
Badge Reels
Strap Clips
Lanyards
Resources
Videos
REGISTER / LOGIN
SHOP
RPL
CART (
0
)
Questions And Answers
#
80
List All Questions
Search
List by Category
Question
We are currently looking for alternatives to hard wiring our wrist strap sockets and table matting, and were hoping if you could tell us if it is sufficient to do the following and still provide a safe ESD environment for PBA manufacturing? "Attach copper strips to the feet of the production tables, then hard wire the wrist strap socket and table matting to the table frame. (Our floor is static dissipative, on average, to between 10to7 & 10to9 ohms per square.) This will allow our tables to be more flexible, as the table doesn't necessarily have to have power to be earthed." - Clayton Gardner, Australian Electronic Manufacturing Services, Sydney, Australia
Answer
I would not recommend wiring your table mats and wrist straps to the ESD floor in luei of a hard ground. Your floor's resistance of 100 Megohms to 1,000 Megohms would not protect you adequately as a "ground substitute" for your wrist strap or table mat. The recommended grounding (for common point grounds, table matting, and wrist straps) is a hard ground that does not exceed 1.0 Ohm according to the ANSI/EOS/ESD-S6.1-1991 under section 4.4.1. One of the biggest concerns to not using a hard ground is the increase in your electronic time constant /RC (discharge time). We have a white paper available on our Web Site that better discusses discharge times. You don't need to have power at the benches to run an "Earth" ground to them. A common ground bus can be used and wired to these benches. An electrician can easily help you with this. You will want to be careful of ground loops for possible electrical noise problems both to sensitive electronic equipment and ESD grounded operators.
Related Categories:
Smocks
If you have found this Q/A useful, please rate it based on its helpfulness.
This question has been rated:
(
0
% at
0
Ratings)
This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Review our
Cookies Policy
for more information.
Accept